- Sat - Thurs: 8am to 4:30pm
Our Services
Laboratory calibration Services
Nuclear Gauge
Calibration Range:
Density (1758.8 to 2725) kg/m³
Moisture (0 to 800) kg/m³
Calibration Method Used: In accordance with ASTM D7759
Some Equipment / Instrument Calibrated Humboldt Troxler Instrotek & C
Moisture (0 to 800) kg/m³
Calibration Method Used: In accordance with ASTM D7759
Some Equipment / Instrument Calibrated Humboldt Troxler Instrotek & C
Temperature
Calibration Range:
-40 to 1200 , standard is DKD-R 5-7 and Euramet CG-8
Calibration Method Used:
In accordance with ASTM D7759
Equipment / Instrument Calibrated
In Lab: Ovens, Thermographic Cameras and IR Temperature equipment
On Site: Ovens, Thermographic Cameras and IR Temperature equipment
Pressure
Calibration Range:
-1 bar Up to 1000 bar Hydraulic
-1 bar up to 200 bar pneumatic.
Equipment / Instrument Calibrated: In Lab: Dead Weight Testers, Pressure Gauges and Calibration
On Site: Dead Weight Testers, Pressure Gauges and Calibrators
-1 bar up to 200 bar pneumatic.
Equipment / Instrument Calibrated: In Lab: Dead Weight Testers, Pressure Gauges and Calibration
On Site: Dead Weight Testers, Pressure Gauges and Calibrators
moisture 0-800
Calibration Range:
Up to 3000 KN
Moisture (0 to 800) kg/m³
Calibration Method Used: ASTM E-74
Equipment / Instrument Calibrated In Lab: Load cells
On Site: Universal Compression machines, Load Rings and CBR/Marshall Machines
Moisture (0 to 800) kg/m³
Calibration Method Used: ASTM E-74
Equipment / Instrument Calibrated In Lab: Load cells
On Site: Universal Compression machines, Load Rings and CBR/Marshall Machines
Mass
Calibration Range:
1 mg up to 1000 kg
Calibration Method Used: OIML RIII-I 2004 (E)
Equipment / Instrument Calibrated In Lab: Standard weights, Weighing balances On Site: Forklifts, Platform Weighing Scales, Cranes, Heavy Chains
Calibration Method Used: OIML RIII-I 2004 (E)
Equipment / Instrument Calibrated In Lab: Standard weights, Weighing balances On Site: Forklifts, Platform Weighing Scales, Cranes, Heavy Chains
Rotational Speed
Calibration Range:
up to 9999 rpm.
Equipment / Instrument Calibrated: In Lab: Centrifuges, Mixers, Motors
Equipment / Instrument Calibrated: In Lab: Centrifuges, Mixers, Motors
Dimension
Calibration Range:
Up to 1000 mm.
Calibration Method Used: In Lab: Micrometers & Vernier calipers, Depth & height gages On Site: Micrometers & Vernier calipers, Depth & height gages
Calibration Method Used: In Lab: Micrometers & Vernier calipers, Depth & height gages On Site: Micrometers & Vernier calipers, Depth & height gages
Sound
Calibration Range:
94 dB & 114 dB
Calibration Method Used: In accordance with ANSI/ASA S1.4-2014/Part 1 Equipment / Instrument CalibratedIn Lab: Sound Level Meters
Calibration Method Used: In accordance with ANSI/ASA S1.4-2014/Part 1 Equipment / Instrument CalibratedIn Lab: Sound Level Meters
Ready To Get Started ?
Contact Us and We’ll Get In Touch
laboratory Equipment and Services
Nuclear Density Gauge
Nuclear Density Gauge is a tool used in civil construction and the petroleum industry, as well as for mining and archaeology purposes. It consists of a radiation source that emits a cloud of particles and a sensor that counts the received particles that are either reflected by the test material or pass through it.
Nuclear Gauge Tool Set
Tool kit includes: rod guide/scraper plate, drill pin, four-pound hammer, pin extraction tool and zippered accessory case.
Nuclear Gauge Containment System
The safety containment box is an enhanced field security system for nuclear gauges. Constructed of heavy-duty steel plate.
Nuclear Density Gauge
Nuclear Density Gauge is a tool used in civil construction and the petroleum industry, as well as for mining and archaeology purposes. It consists of a radiation source that emits a cloud of particles and a sensor that counts the received particles that are either reflected by the test material or pass through it.
We Provide the best Equipment meeting all requirements of the Ministry of Municipality and Environment and we provide also Calibration and maintenance services.
Nuclear Gauge Tool Set
Tool kit includes: rod guide/scraper plate, drill pin, four-pound hammer, pin extraction tool and zippered accessory case.
We Provide the best Equipment meeting all requirements of the Ministry of Municipality.
Radiation Safety System
The Radiation-Safety Kit is designed to provide a better solution in case of physical damage of the Nuclear Gauge.
We Provide the best Equipment meeting all requirements of the Ministry of Municipality and Environment with the best price.
Lab Equipment
As our innovation we will be the leading company in Civil Engineering testing equipment suppling. For instance, concrete, soil, asphalt and bitumen, rock and steel.
Our company established since year 2018. We are widely distributing to many large/big scale civil engineering company and laboratory.
TLD Badges
A thermo luminescent dosimeter, or TLD, is a type of radiation dosimeter. A TLD measures ionizing radiation exposure by measuring the intensity of visible light emitted by a crystal inside the detector when the crystal is heated. The intensity of light emitted is dependent upon the radiation exposure.
We offer competitive pricing and No Hidden Fees for our dosimeter badge service.
Survey Meters and Radiation Monitoring Equipment
The Radiation-Safety Kit is designed to provide a better solution in case of physical damage of the Nuclear Gauge.
We Provide the best Equipment meeting all requirements of the Ministry of Municipality and Environment with the best price.
Training
We provide a Training Program focused on continuing regulatory and industry education for moisture density portable nuclear gauge owners and operators. Precision Calibration strives to offer the viewer the most in-depth and comprehensive coverage of regulations, issues, references and resources and is dedicated to covering just the material pertaining to moisture density gauges.
All our Training Programs are meeting all requirements of the Ministry of Municipality and Environment.